- The PVC housing of MCL is impact resistant and non-inflammable - and has advantage from accidents of short and electric shock. - Also, this system can be used the electric power and control line at the same time. |
|
|
- There is no Arc because the copper is jointless. - It is possible to transmit for a data & signal and to use for a parallel system. - There has 50, 80, 125, 160A current capacity. |
|
|
- The collector trolley can not be a breakaway from housing inside and also can be - a moving of high speed(over 250m/min. depend on the collector trolley) running. - The abrasion rate of carbon brush is low due to a jointless copper conductor. |
|
|
The Sliding hanger can be protected vibration and complemented shrinkage and expanding depend on ambient temperature condition. The Rubber covering can be installed in harsh environments. It can be installed at outside, narrow space and also reduced the cost due to a using of semipermanent. |
|
|
|
|
- gasoline crude, benzene,sodium, hydrochloric acid |
|
|
- Minmum : R = 800 mm |
|
|
- Bending force : 831kp/㎠(831 x 14.2psi) - Tensile strength : 491kp/㎠, Elongation 3.2% - Breaking strength : 345kp/㎠, Elongation 36% |
|
|
- Straight line : 250 m/min |
|
-
- Min. ambient temperatures
|
- -30℃ to +60℃(standard design) |
|
-
- Calculation of voltage-drop
|
AC : △u = √ 3 x J x I x Z / 1000 |
DC : △u = 2I x J x R / 1000 |
△u = Voltage(V) |
J = Amperage(A) |
Z = Impedance ohms / 1000(m) |
R = Resistance ohms / 1000(m) |
L = Length(m) |
I = L Power feed positioned at end |
L/2 Power feed positioned at center |
|
|
|
- Voltage : AC 600V - Creepage path : min. 30㎜ - Dielectric strength : 31.2kv/㎜ - Surface resistance : 11 x 10ohm x cm(dry) |
|
|
- PVC Housing: MCL7 - Standard length: 4,000mm - Material: non-inflammable - Structure: In order to prevent a changing of phase, it is safe structure when the position of collector is changed. |
|
|
- It can be used for 4 to 7poles, non-Arc due to jointness of copper, for 50, 80, 125 & 160A and also max.320A with parallel connection. - There is yellow line for an earthing conductor beside housing. - It is easy an instllation and standard length is 4m long. - The rubber-covering can be installed in harsh environments, narrow space& outside area and also the housing & copper can be used for a semipermanent. |
|
|